{"id":8189,"date":"2025-07-25T14:51:29","date_gmt":"2025-07-25T06:51:29","guid":{"rendered":"https:\/\/www.stvvalves.com\/?p=8189"},"modified":"2025-07-25T22:14:01","modified_gmt":"2025-07-25T14:14:01","slug":"api-598-valve-inspection-testing-standard-complete-guide","status":"publish","type":"post","link":"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/","title":{"rendered":"API 598: Valve Inspection &#038; Testing Standard (Complete Guide)"},"content":{"rendered":"<p class=\"ds-markdown-paragraph\"><strong>\u0623\u0628\u064a 598<\/strong>\u00a0is the\u00a0<strong>American Petroleum Institute (API) standard<\/strong>\u00a0that defines\u00a0<strong>inspection and testing requirements<\/strong>\u00a0for industrial valves, including:<br \/>\n\u2714\u00a0<strong>Pressure tests<\/strong>\u00a0(shell, seat, backseat)<br \/>\n\u2714\u00a0<strong>Leakage criteria<\/strong>\u00a0(allowable rates)<br \/>\n\u2714\u00a0<strong>Test procedures<\/strong>\u00a0(duration, media, pressure levels)<\/p>\n<p class=\"ds-markdown-paragraph\">It applies to\u00a0<strong>gate, globe, check, ball, and butterfly valves<\/strong>\u00a0used in oil &amp; gas, petrochemical, and other high-pressure industries.<\/p>\n<hr \/>\n<div id=\"attachment_8194\" style=\"width: 1010px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-8194\" class=\"wp-image-8194 size-full\" src=\"https:\/\/www.stvvalves.com\/wp-content\/uploads\/2025\/07\/API598-Gate-Valve-Test.jpg\" alt=\"API598 Gate Valve\" width=\"1000\" height=\"1000\" srcset=\"https:\/\/www.stvvalves.com\/wp-content\/uploads\/2025\/07\/API598-Gate-Valve-Test.jpg 1000w, https:\/\/www.stvvalves.com\/wp-content\/uploads\/2025\/07\/API598-Gate-Valve-Test-300x300.jpg 300w, https:\/\/www.stvvalves.com\/wp-content\/uploads\/2025\/07\/API598-Gate-Valve-Test-80x80.jpg 80w, https:\/\/www.stvvalves.com\/wp-content\/uploads\/2025\/07\/API598-Gate-Valve-Test-768x768.jpg 768w, https:\/\/www.stvvalves.com\/wp-content\/uploads\/2025\/07\/API598-Gate-Valve-Test-12x12.jpg 12w, https:\/\/www.stvvalves.com\/wp-content\/uploads\/2025\/07\/API598-Gate-Valve-Test-36x36.jpg 36w, https:\/\/www.stvvalves.com\/wp-content\/uploads\/2025\/07\/API598-Gate-Valve-Test-180x180.jpg 180w, https:\/\/www.stvvalves.com\/wp-content\/uploads\/2025\/07\/API598-Gate-Valve-Test-705x705.jpg 705w, https:\/\/www.stvvalves.com\/wp-content\/uploads\/2025\/07\/API598-Gate-Valve-Test-120x120.jpg 120w, https:\/\/www.stvvalves.com\/wp-content\/uploads\/2025\/07\/API598-Gate-Valve-Test-450x450.jpg 450w, https:\/\/www.stvvalves.com\/wp-content\/uploads\/2025\/07\/API598-Gate-Valve-Test-600x600.jpg 600w, https:\/\/www.stvvalves.com\/wp-content\/uploads\/2025\/07\/API598-Gate-Valve-Test-100x100.jpg 100w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><p id=\"caption-attachment-8194\" class=\"wp-caption-text\">API598 Gate Valve Test,300LB API598 Gate Valve Test<\/p><\/div>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_84 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/#%F0%9F%94%B9_Key_Tests_Under_API_598\" >\ud83d\udd39 Key Tests Under API 598<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/#1_Shell_Test_Pressure_Integrity_Test\" >1. Shell Test (Pressure Integrity Test)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/#2_Seat_Test_Leakage_Test\" >2. Seat Test (Leakage Test)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/#3_Backseat_Test_Stem_Seal_Test_%E2%80%93_for_Rising_Stem_Valves\" >3. Backseat Test (Stem Seal Test \u2013 for Rising Stem Valves)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/#4_High-Pressure_Gas_Test_Optional_for_Severe_Service\" >4. High-Pressure Gas Test (Optional, for Severe Service)<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/#%F0%9F%94%B9_API_598_Leakage_Allowance_Max_Permitted_Leak_Rates\" >\ud83d\udd39 API 598 Leakage Allowance (Max Permitted Leak Rates)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/#%F0%9F%94%B9_API_598_vs_Other_Valve_Testing_Standards\" >\ud83d\udd39 API 598 vs. Other Valve Testing Standards<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/#%F0%9F%94%B9_When_is_API_598_Testing_Required\" >\ud83d\udd39 When is API 598 Testing Required?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/#%F0%9F%94%B9_How_to_Verify_API_598_Compliance\" >\ud83d\udd39 How to Verify API 598 Compliance?<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/#Final_Summary\" >Final Summary<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/#API_598_vs_ISO_5208_Valve_Testing_Standards_Compared\" >API 598 vs. ISO 5208: Valve Testing Standards Compared<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/#%F0%9F%94%B9_Key_Differences_API_598_vs_ISO_5208\" >\ud83d\udd39 Key Differences: API 598 vs. ISO 5208<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/#%F0%9F%94%B9_Leakage_Rate_Comparison\" >\ud83d\udd39 Leakage Rate Comparison<\/a><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/#API_598_Strict\" >API 598 (Strict)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/#ISO_5208_Class-Based\" >ISO 5208 (Class-Based)<\/a><\/li><\/ul><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-16\" href=\"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/#%F0%9F%94%B9_How_to_Interpret_a_Valve_Test_Report\" >\ud83d\udd39 How to Interpret a Valve Test Report<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-17\" href=\"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/#1_Valve_Identification\" >1. Valve Identification<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-18\" href=\"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/#2_Test_Conditions\" >2. Test Conditions<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-19\" href=\"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/#3_Results\" >3. Results<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-20\" href=\"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/#4_Certification_Marks\" >4. Certification Marks<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-21\" href=\"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/#%F0%9F%94%B9_Which_Standard_Should_You_Use\" >\ud83d\udd39 Which Standard Should You Use?<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-22\" href=\"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/#%F0%9F%94%B9_Need_Help_Deciding\" >\ud83d\udd39 Need Help Deciding?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-23\" href=\"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/#Final_Advice\" >Final Advice<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-24\" href=\"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/#How_to_Review_a_Valve_Test_Report_Step-by-Step_Guide\" >How to Review a Valve Test Report (Step-by-Step Guide)<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-25\" href=\"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/#1_Key_Details_to_Check_in_a_Valve_Test_Report\" >1. Key Details to Check in a Valve Test Report<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-26\" href=\"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/#%F0%9F%94%B9_Valve_Identification\" >\ud83d\udd39 Valve Identification<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-27\" href=\"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/#%F0%9F%94%B9_Test_Standards_Applied\" >\ud83d\udd39 Test Standards Applied<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-28\" href=\"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/#%F0%9F%94%B9_Test_Parameters\" >\ud83d\udd39 Test Parameters<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-29\" href=\"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/#%F0%9F%94%B9_Leakage_Results\" >\ud83d\udd39 Leakage Results<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-30\" href=\"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/#%F0%9F%94%B9_Certifications_Inspector_Sign-Off\" >\ud83d\udd39 Certifications &amp; Inspector Sign-Off<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-31\" href=\"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/#2_Example_Test_Report_Breakdown\" >2. Example Test Report Breakdown<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-32\" href=\"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/#3_Common_Red_Flags_in_Test_Reports\" >3. Common Red Flags in Test Reports<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-33\" href=\"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/#4_How_to_Share_Your_Report_for_Review\" >4. How to Share Your Report for Review<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-34\" href=\"https:\/\/www.stvvalves.com\/ar\/api-598-valve-inspection-testing-standard-complete-guide\/#5_Need_Immediate_Help\" >5. Need Immediate Help?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"%F0%9F%94%B9_Key_Tests_Under_API_598\"><\/span><strong>\ud83d\udd39 Key Tests Under <a href=\"https:\/\/dl.gasplus.ir\/standard-ha\/standard-API\/API%20598%202023.pdf\" target=\"_blank\" rel=\"noopener\">\u0623\u0628\u064a 598<\/a><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3><span class=\"ez-toc-section\" id=\"1_Shell_Test_Pressure_Integrity_Test\"><\/span><strong>1. Shell Test (Pressure Integrity Test)<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Purpose:<\/strong>\u00a0Checks valve body &amp; seal strength.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Test Medium:<\/strong>\u00a0Water, air, or kerosene (non-shock test).<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Pressure:<\/strong>\u00a0<strong>1.5x<\/strong>\u00a0valve\u2019s rated pressure (e.g., Class 300 valve tested at 750 psi).<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Duration:<\/strong>\u00a0At least\u00a0<strong>60 seconds<\/strong>\u00a0for liquid,\u00a0<strong>30 seconds<\/strong>\u00a0for gas.<\/p>\n<\/li>\n<\/ul>\n<h3><span class=\"ez-toc-section\" id=\"2_Seat_Test_Leakage_Test\"><\/span><strong>2. Seat Test (Leakage Test)<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Purpose:<\/strong>\u00a0Ensures sealing performance (no leaks).<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Test Medium:<\/strong>\u00a0Water, air, or inert gas (nitrogen).<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Pressure:<\/strong>\u00a0<strong>1.1x<\/strong>\u00a0rated pressure (e.g., Class 150 valve tested at 165 psi).<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Acceptable Leakage:<\/strong>\u00a0Depends on valve type (see table below).<\/p>\n<\/li>\n<\/ul>\n<h3><span class=\"ez-toc-section\" id=\"3_Backseat_Test_Stem_Seal_Test_%E2%80%93_for_Rising_Stem_Valves\"><\/span><strong>3. Backseat Test (Stem Seal Test \u2013 for Rising Stem Valves)<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Purpose:<\/strong>\u00a0Verifies stem sealing when fully open.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Test Pressure:<\/strong>\u00a0Same as shell test.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Leakage Allowed:<\/strong>\u00a0<strong>\u0635\u0641\u0631 \u062a\u0633\u0631\u0628<\/strong>\u00a0(must be bubble-tight).<\/p>\n<\/li>\n<\/ul>\n<h3><span class=\"ez-toc-section\" id=\"4_High-Pressure_Gas_Test_Optional_for_Severe_Service\"><\/span><strong>4. High-Pressure Gas Test (Optional, for Severe Service)<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Purpose:<\/strong>\u00a0Extra validation for critical valves (e.g., hydrogen service).<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Test Medium:<\/strong>\u00a0Nitrogen or helium.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Pressure:<\/strong>\u00a0Up to\u00a0<strong>1.5x<\/strong>\u00a0rated pressure.<\/p>\n<\/li>\n<\/ul>\n<hr \/>\n<div id=\"attachment_8195\" style=\"width: 1210px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-8195\" class=\"wp-image-8195 size-full\" src=\"https:\/\/www.stvvalves.com\/wp-content\/uploads\/2025\/07\/API-598-Ball-Valve-Test.jpg\" alt=\"API598 ball valve test\" width=\"1200\" height=\"899\" srcset=\"https:\/\/www.stvvalves.com\/wp-content\/uploads\/2025\/07\/API-598-Ball-Valve-Test.jpg 1200w, https:\/\/www.stvvalves.com\/wp-content\/uploads\/2025\/07\/API-598-Ball-Valve-Test-300x225.jpg 300w, https:\/\/www.stvvalves.com\/wp-content\/uploads\/2025\/07\/API-598-Ball-Valve-Test-1030x772.jpg 1030w, https:\/\/www.stvvalves.com\/wp-content\/uploads\/2025\/07\/API-598-Ball-Valve-Test-768x575.jpg 768w, https:\/\/www.stvvalves.com\/wp-content\/uploads\/2025\/07\/API-598-Ball-Valve-Test-16x12.jpg 16w, https:\/\/www.stvvalves.com\/wp-content\/uploads\/2025\/07\/API-598-Ball-Valve-Test-705x528.jpg 705w, https:\/\/www.stvvalves.com\/wp-content\/uploads\/2025\/07\/API-598-Ball-Valve-Test-450x337.jpg 450w, https:\/\/www.stvvalves.com\/wp-content\/uploads\/2025\/07\/API-598-Ball-Valve-Test-600x450.jpg 600w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><p id=\"caption-attachment-8195\" class=\"wp-caption-text\">Ball Valves Covered by API 598<\/p><\/div>\n<h2><span class=\"ez-toc-section\" id=\"%F0%9F%94%B9_API_598_Leakage_Allowance_Max_Permitted_Leak_Rates\"><\/span><strong>\ud83d\udd39 API 598 Leakage Allowance (Max Permitted Leak Rates)<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<div class=\"markdown-table-wrapper\">\n<table>\n<thead>\n<tr>\n<th><strong>\u0646\u0648\u0639 \u0627\u0644\u0635\u0645\u0627\u0645<\/strong><\/th>\n<th><strong>Test Medium<\/strong><\/th>\n<th><strong>Max Leakage Allowed<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Gate, Globe<\/strong><\/td>\n<td>Liquid (water)<\/td>\n<td><strong>0 drops\/min (bubble-tight)<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Ball, Plug<\/strong><\/td>\n<td>Gas (air)<\/td>\n<td><strong>\u2264 20 bubbles\/min (DN \u2264 100mm)<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u0641\u062d\u0635 \u0627\u0644\u0635\u0645\u0627\u0645\u0627\u062a<\/strong><\/td>\n<td>Liquid<\/td>\n<td><strong>0.1 mL\/min per inch of seat diameter<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Butterfly Valves<\/strong><\/td>\n<td>Gas<\/td>\n<td><strong>\u2264 100 mL\/min per inch of seat diameter<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"ds-markdown-paragraph\"><em>(DN = Nominal Diameter in mm)<\/em><\/p>\n<hr \/>\n<h2><span class=\"ez-toc-section\" id=\"%F0%9F%94%B9_API_598_vs_Other_Valve_Testing_Standards\"><\/span><strong>\ud83d\udd39 API 598 vs. Other Valve Testing Standards<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<div class=\"markdown-table-wrapper\">\n<table>\n<thead>\n<tr>\n<th><strong>\u0645\u0639\u064a\u0627\u0631<\/strong><\/th>\n<th><strong>Scope<\/strong><\/th>\n<th><strong>Key Difference<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>\u0623\u0628\u064a 598<\/strong><\/td>\n<td>General valve testing (oil &amp; gas)<\/td>\n<td>Stricter than MSS SP-61, less severe than API 6D<\/td>\n<\/tr>\n<tr>\n<td><strong>API 6D<\/strong><\/td>\n<td>Pipeline valves<\/td>\n<td>Includes\u00a0<strong>fire-safe testing (API 607\/6FA)<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u0623\u0633\u0645 B16.34<\/strong><\/td>\n<td>Pressure-temperature ratings<\/td>\n<td>Does not define leakage rates<\/td>\n<\/tr>\n<tr>\n<td><strong>ISO 5208<\/strong><\/td>\n<td>Global equivalent of API 598<\/td>\n<td>Similar but uses different leakage classes (A to G)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<hr \/>\n<h2><span class=\"ez-toc-section\" id=\"%F0%9F%94%B9_When_is_API_598_Testing_Required\"><\/span><strong>\ud83d\udd39 When is API 598 Testing Required?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p class=\"ds-markdown-paragraph\">\u2705\u00a0<strong>New valve manufacturing<\/strong>\u00a0(mandatory for API-certified valves)<br \/>\n\u2705\u00a0<strong>Repair\/refurbishment<\/strong>\u00a0(after maintenance or re-seating)<br \/>\n\u2705\u00a0<strong>Customer-requested validation<\/strong>\u00a0(for critical applications)<\/p>\n<hr \/>\n<h2><span class=\"ez-toc-section\" id=\"%F0%9F%94%B9_How_to_Verify_API_598_Compliance\"><\/span><strong>\ud83d\udd39 How to Verify API 598 Compliance?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p class=\"ds-markdown-paragraph\">\u2714 Check the\u00a0<strong>valve nameplate<\/strong>\u00a0for API markings.<br \/>\n\u2714 Request\u00a0<strong>test reports<\/strong>\u00a0(shell\/seat test results).<br \/>\n\u2714 Look for\u00a0<strong>third-party inspection stamps<\/strong>\u00a0(e.g., Lloyd\u2019s, DNV).<\/p>\n<hr \/>\n<h3><span class=\"ez-toc-section\" id=\"Final_Summary\"><\/span><strong>Final Summary<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>\u0623\u0628\u064a 598<\/strong>\u00a0ensures valves can handle\u00a0<strong>rated pressure without leaking<\/strong>.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Shell test = strength check<\/strong>,\u00a0<strong>seat test = sealing check<\/strong>.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Ball\/plug valves<\/strong>\u00a0allow minor gas leakage, while\u00a0<strong>gate\/globe valves<\/strong>\u00a0must be\u00a0<strong>bubble-tight<\/strong>.<\/p>\n<\/li>\n<li>\n<h3><span class=\"ez-toc-section\" id=\"API_598_vs_ISO_5208_Valve_Testing_Standards_Compared\"><\/span><strong>API 598 vs. ISO 5208: Valve Testing Standards Compared<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p class=\"ds-markdown-paragraph\"><strong>Both standards<\/strong>\u00a0define valve testing procedures, but they differ in\u00a0<strong>scope, leakage allowances, and global acceptance<\/strong>. Here\u2019s a detailed breakdown:<\/p>\n<hr \/>\n<h2><span class=\"ez-toc-section\" id=\"%F0%9F%94%B9_Key_Differences_API_598_vs_ISO_5208\"><\/span><strong>\ud83d\udd39 Key Differences: API 598 vs. ISO 5208<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<div class=\"markdown-table-wrapper\">\n<table>\n<thead>\n<tr>\n<th><strong>Feature<\/strong><\/th>\n<th><strong>\u0623\u0628\u064a 598<\/strong>\u00a0(American Petroleum Institute)<\/th>\n<th><strong>ISO 5208<\/strong>\u00a0(International Org. for Standardization)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Primary Use<\/strong><\/td>\n<td>Oil &amp; gas, petrochemical, high-pressure<\/td>\n<td>General industrial, water, European markets<\/td>\n<\/tr>\n<tr>\n<td><strong>Leakage Classes<\/strong><\/td>\n<td>No formal classes (fixed pass\/fail)<\/td>\n<td><strong>A to G<\/strong>\u00a0(A = zero leakage, G = highest allowance)<\/td>\n<\/tr>\n<tr>\n<td><strong>Test Pressures<\/strong><\/td>\n<td>Shell:\u00a0<strong>1.5x<\/strong>\u00a0rated pressure<br \/>\nSeat:\u00a0<strong>1.1x<\/strong><\/td>\n<td>Shell:\u00a0<strong>1.5x<\/strong><br \/>\nSeat:\u00a0<strong>1.1x<\/strong>\u00a0(similar)<\/td>\n<\/tr>\n<tr>\n<td><strong>Acceptable Leakage<\/strong><\/td>\n<td>Stricter for gas tests (e.g., ball valves: \u226420 bubbles\/min)<\/td>\n<td>More flexible (Class D allows droplets)<\/td>\n<\/tr>\n<tr>\n<td><strong>Backseat Test<\/strong><\/td>\n<td>Required for rising-stem valves<\/td>\n<td>Optional<\/td>\n<\/tr>\n<tr>\n<td><strong>Fire Testing<\/strong><\/td>\n<td>Not included (separate: API 607\/6FA)<\/td>\n<td>Not included<\/td>\n<\/tr>\n<tr>\n<td><strong>Global Adoption<\/strong><\/td>\n<td>Dominant in\u00a0<strong>North America, Middle East<\/strong><\/td>\n<td>Widely used in\u00a0<strong>Europe, Asia<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<hr \/>\n<h3><span class=\"ez-toc-section\" id=\"%F0%9F%94%B9_Leakage_Rate_Comparison\"><\/span><strong>\ud83d\udd39 Leakage Rate Comparison<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<h4><span class=\"ez-toc-section\" id=\"API_598_Strict\"><\/span><strong><a href=\"https:\/\/www.stvvalves.com\/ar\/what-is-the-api-598-leak-testing-of-valves\/\">\u0623\u0628\u064a 598<\/a> (Strict)<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h4>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Ball\/Plug Valves (Gas Test):<\/strong>\u00a0\u226420 bubbles\/min (for DN \u2264100mm)<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Gate\/Globe Valves:<\/strong>\u00a0<strong>\u0635\u0641\u0631 \u062a\u0633\u0631\u0628<\/strong>\u00a0(bubble-tight)<\/p>\n<\/li>\n<\/ul>\n<h4><span class=\"ez-toc-section\" id=\"ISO_5208_Class-Based\"><\/span><strong>ISO 5208 (Class-Based)<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h4>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Class A:<\/strong>\u00a0Zero leakage (like API 598)<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Class D:<\/strong>\u00a0Allows\u00a0<strong>droplets<\/strong>\u00a0(common for general-purpose valves)<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Class G:<\/strong>\u00a0Highest leakage allowance (e.g., for wastewater valves)<\/p>\n<\/li>\n<\/ul>\n<hr \/>\n<h2><span class=\"ez-toc-section\" id=\"%F0%9F%94%B9_How_to_Interpret_a_Valve_Test_Report\"><\/span><strong>\ud83d\udd39 How to Interpret a Valve Test Report<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p class=\"ds-markdown-paragraph\">A typical\u00a0<strong>API 598\/ISO 5208 test report<\/strong>\u00a0includes:<\/p>\n<h3><span class=\"ez-toc-section\" id=\"1_Valve_Identification\"><\/span><strong>1. Valve Identification<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\">Manufacturer, size, model, serial number<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\">Pressure class (e.g., Class 300)<\/p>\n<\/li>\n<\/ul>\n<h3><span class=\"ez-toc-section\" id=\"2_Test_Conditions\"><\/span><strong>2. Test Conditions<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Medium:<\/strong>\u00a0Water, air, or nitrogen<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Shell Test Pressure:<\/strong>\u00a0(e.g., 750 psi for Class 300)<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Seat Test Pressure:<\/strong>\u00a0(e.g., 330 psi for Class 300)<\/p>\n<\/li>\n<\/ul>\n<h3><span class=\"ez-toc-section\" id=\"3_Results\"><\/span><strong>3. Results<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<div class=\"markdown-table-wrapper\">\n<table>\n<thead>\n<tr>\n<th><strong>Test Type<\/strong><\/th>\n<th><strong>Pressure Held<\/strong><\/th>\n<th><strong>Duration<\/strong><\/th>\n<th><strong>Leakage Observed<\/strong><\/th>\n<th><strong>Pass\/Fail<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Shell Test<\/td>\n<td>750 psi<\/td>\n<td>60 sec<\/td>\n<td>None<\/td>\n<td>\u2705 Pass<\/td>\n<\/tr>\n<tr>\n<td>Seat Test<\/td>\n<td>330 psi<\/td>\n<td>60 sec<\/td>\n<td>5 bubbles\/min<\/td>\n<td>\u2705 Pass (API 598 allows \u226420)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h3><span class=\"ez-toc-section\" id=\"4_Certification_Marks\"><\/span><strong>4. Certification Marks<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>API Monogram<\/strong>\u00a0(if API 598 certified)<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>ISO 5208 Class<\/strong>\u00a0(e.g., &#8220;ISO 5208 Class A&#8221;)<\/p>\n<\/li>\n<\/ul>\n<hr \/>\n<h2><span class=\"ez-toc-section\" id=\"%F0%9F%94%B9_Which_Standard_Should_You_Use\"><\/span><strong>\ud83d\udd39 Which Standard Should You Use?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>For oil\/gas, refineries:<\/strong>\u00a0<strong>\u0623\u0628\u064a 598<\/strong>\u00a0(mandatory in many specs)<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>For water, HVAC, EU projects:<\/strong>\u00a0<strong>ISO 5208<\/strong>\u00a0(often Class D)<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Zero-leakage critical apps:<\/strong>\u00a0Both allow it (API 598 or ISO Class A)<\/p>\n<\/li>\n<\/ul>\n<hr \/>\n<h3><span class=\"ez-toc-section\" id=\"%F0%9F%94%B9_Need_Help_Deciding\"><\/span><strong>\ud83d\udd39 Need Help Deciding?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>If your valve test report shows ISO Class D leakage<\/strong>, it may\u00a0<strong>not meet API 598<\/strong>\u00a0(which is stricter).<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>For fire-safe valves<\/strong>, you\u2019ll need\u00a0<strong>API 607\/6FA<\/strong>\u00a0in addition to API 598.<\/p>\n<\/li>\n<\/ul>\n<p class=\"ds-markdown-paragraph\"><strong>Example Scenario:<\/strong><\/p>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\">\u0623\u00a0<strong>\u0635\u0645\u0627\u0645 \u0627\u0644\u0643\u0631\u0629<\/strong>\u00a0passes\u00a0<strong>ISO 5208 Class D<\/strong>\u00a0(allowing droplets) but\u00a0<strong>fails API 598<\/strong>\u00a0(which requires \u226420 bubbles\/min for gas tests).<\/p>\n<\/li>\n<\/ul>\n<hr \/>\n<h3><span class=\"ez-toc-section\" id=\"Final_Advice\"><\/span><strong>Final Advice<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p class=\"ds-markdown-paragraph\">\u2714\u00a0<strong>Check project specs<\/strong>\u00a0\u2013 Many contracts explicitly require\u00a0<strong>\u0623\u0628\u064a 598<\/strong>.<br \/>\n\u2714\u00a0<strong>For zero leakage<\/strong>, demand\u00a0<strong>ISO 5208 Class A<\/strong>\u00a0or\u00a0<strong>API 598 bubble-tight<\/strong>.<br \/>\n\u2714\u00a0<strong>When in doubt<\/strong>, request\u00a0<strong>both tests<\/strong>\u00a0for critical valves.<\/p>\n<\/li>\n<li>\n<h3><span class=\"ez-toc-section\" id=\"How_to_Review_a_Valve_Test_Report_Step-by-Step_Guide\"><\/span><strong>How to Review a Valve Test Report (Step-by-Step Guide)<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p class=\"ds-markdown-paragraph\">If you have a\u00a0<strong>specific valve test report<\/strong>\u00a0(API 598, ISO 5208, or other), share the following details, and I\u2019ll help you interpret it:<\/p>\n<hr \/>\n<h2><span class=\"ez-toc-section\" id=\"1_Key_Details_to_Check_in_a_Valve_Test_Report\"><\/span><strong>1. Key Details to Check in a Valve Test Report<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3><span class=\"ez-toc-section\" id=\"%F0%9F%94%B9_Valve_Identification\"><\/span><strong>\ud83d\udd39 Valve Identification<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\">Manufacturer name &amp; valve model<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\">Size (e.g., 2&#8243; DN50)<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\">Pressure class (e.g., Class 150, PN16)<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\">Serial number &amp; date of testing<\/p>\n<\/li>\n<\/ul>\n<h3><span class=\"ez-toc-section\" id=\"%F0%9F%94%B9_Test_Standards_Applied\"><\/span><strong>\ud83d\udd39 Test Standards Applied<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\">Is it\u00a0<strong>API 598, ISO 5208, ASME B16.34, or another standard?<\/strong><\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\">If ISO 5208, what\u00a0<strong>leakage class<\/strong>\u00a0(A, B, C, D, etc.)?<\/p>\n<\/li>\n<\/ul>\n<h3><span class=\"ez-toc-section\" id=\"%F0%9F%94%B9_Test_Parameters\"><\/span><strong>\ud83d\udd39 Test Parameters<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Shell test pressure<\/strong>\u00a0(usually\u00a0<strong>1.5x<\/strong>\u00a0rated pressure)<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Seat test pressure<\/strong>\u00a0(usually\u00a0<strong>1.1x<\/strong>\u00a0rated pressure)<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Test medium<\/strong>\u00a0(water, air, nitrogen, etc.)<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Duration<\/strong>\u00a0(e.g., 60 sec for shell, 30 sec for seat)<\/p>\n<\/li>\n<\/ul>\n<h3><span class=\"ez-toc-section\" id=\"%F0%9F%94%B9_Leakage_Results\"><\/span><strong>\ud83d\udd39 Leakage Results<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Shell test leakage<\/strong>\u00a0(should be\u00a0<strong>zero<\/strong>\u00a0for API 598)<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Seat test leakage<\/strong>\u00a0(compare against allowed rates)<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Backseat test<\/strong>\u00a0(if applicable, must be bubble-tight)<\/p>\n<\/li>\n<\/ul>\n<h3><span class=\"ez-toc-section\" id=\"%F0%9F%94%B9_Certifications_Inspector_Sign-Off\"><\/span><strong>\ud83d\udd39 Certifications &amp; Inspector Sign-Off<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>API Monogram<\/strong>\u00a0(if API 598 certified)<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Third-party inspection stamps<\/strong>\u00a0(e.g., Lloyd\u2019s, DNV, T\u00dcV)<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Inspector name &amp; date<\/strong><\/p>\n<\/li>\n<\/ul>\n<hr \/>\n<h2><span class=\"ez-toc-section\" id=\"2_Example_Test_Report_Breakdown\"><\/span><strong>2. Example Test Report Breakdown<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p class=\"ds-markdown-paragraph\"><em>(You can replace this with your actual report data for analysis)<\/em><\/p>\n<div class=\"markdown-table-wrapper\">\n<table>\n<thead>\n<tr>\n<th><strong>Test Type<\/strong><\/th>\n<th><strong>Pressure (psi)<\/strong><\/th>\n<th><strong>Duration<\/strong><\/th>\n<th><strong>Leakage Observed<\/strong><\/th>\n<th><strong>Requirement<\/strong><\/th>\n<th><strong>Pass\/Fail?<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Shell Test<\/strong><\/td>\n<td>450 (1.5x Class 300)<\/td>\n<td>60 sec<\/td>\n<td>None<\/td>\n<td>\u0635\u0641\u0631 \u062a\u0633\u0631\u0628<\/td>\n<td>\u2705\u00a0<strong>Pass<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Seat Test (Gas)<\/strong><\/td>\n<td>330 (1.1x Class 300)<\/td>\n<td>30 sec<\/td>\n<td>15 bubbles\/min<\/td>\n<td>\u226420 bubbles\/min (API 598)<\/td>\n<td>\u2705\u00a0<strong>Pass<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Backseat Test<\/strong><\/td>\n<td>450<\/td>\n<td>60 sec<\/td>\n<td>None<\/td>\n<td>\u0635\u0641\u0631 \u062a\u0633\u0631\u0628<\/td>\n<td>\u2705\u00a0<strong>Pass<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"ds-markdown-paragraph\"><strong>Conclusion:<\/strong>\u00a0This valve\u00a0<strong>meets API 598 standards<\/strong>\u00a0since leakage is within limits.<\/p>\n<hr \/>\n<h2><span class=\"ez-toc-section\" id=\"3_Common_Red_Flags_in_Test_Reports\"><\/span><strong>3. Common Red Flags in Test Reports<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p class=\"ds-markdown-paragraph\">\u274c\u00a0<strong>&#8220;N\/A&#8221; or missing tests<\/strong>\u00a0(e.g., no backseat test for a rising-stem valve)<br \/>\n\u274c\u00a0<strong>Leakage exceeds limits<\/strong>\u00a0(e.g., seat test shows 30 bubbles\/min when max is 20)<br \/>\n\u274c\u00a0<strong>No inspector sign-off<\/strong>\u00a0(uncertified tests are unreliable)<br \/>\n\u274c\u00a0<strong>Pressure not held for full duration<\/strong>\u00a0(e.g., test aborted at 45 sec instead of 60 sec)<\/p>\n<hr \/>\n<h2><span class=\"ez-toc-section\" id=\"4_How_to_Share_Your_Report_for_Review\"><\/span><strong>4. How to Share Your Report for Review<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p class=\"ds-markdown-paragraph\">If you have a\u00a0<strong>PDF, image, or data table<\/strong>, provide:<\/p>\n<ol start=\"1\">\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>\u0646\u0648\u0639 \u0627\u0644\u0635\u0645\u0627\u0645<\/strong>\u00a0(ball, gate, etc.)<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Size &amp; pressure rating<\/strong><\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Test standard used<\/strong>\u00a0(API 598, ISO 5208, etc.)<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Leakage results<\/strong>\u00a0(if any)<\/p>\n<\/li>\n<\/ol>\n<p class=\"ds-markdown-paragraph\">*(Example: &#8220;2&#8221; SS316 ball valve, Class 150, API 598 test. Seat test showed 25 bubbles\/min\u2014is this acceptable?&#8221;)*<\/p>\n<hr \/>\n<h3><span class=\"ez-toc-section\" id=\"5_Need_Immediate_Help\"><\/span><strong>5. Need Immediate Help?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p class=\"ds-markdown-paragraph\">\ud83d\udc49\u00a0<strong>For API 598:<\/strong>\u00a0Ensure leakage is within Table 5 limits.<br \/>\n\ud83d\udc49\u00a0<strong>For ISO 5208:<\/strong>\u00a0Check if leakage matches the declared class (A-G).<br \/>\n\ud83d\udc49\u00a0<strong>For fire-safe valves:<\/strong>\u00a0Verify if\u00a0<strong>API 607\/6FA<\/strong>\u00a0tests were done separately.<\/p>\n<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>API 598\u00a0is the\u00a0American Petroleum Institute (API) standard\u00a0that defines\u00a0inspection and testing requirements\u00a0for industrial valves, including: \u2714\u00a0Pressure tests\u00a0(shell, seat, backseat) \u2714\u00a0Leakage criteria\u00a0(allowable rates) \u2714\u00a0Test procedures\u00a0(duration, media, pressure levels) It applies to\u00a0gate, globe, check, ball, and butterfly valves\u00a0used in oil &amp; gas, petrochemical, and other high-pressure industries. \ud83d\udd39 Key Tests Under API 598 1. Shell Test (Pressure Integrity [&hellip;]<\/p>\n","protected":false},"author":290641,"featured_media":8195,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[16],"tags":[3556],"class_list":["post-8189","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-news","tag-api-598-valve-inspection-testing-standard"],"_links":{"self":[{"href":"https:\/\/www.stvvalves.com\/ar\/wp-json\/wp\/v2\/posts\/8189","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.stvvalves.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.stvvalves.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.stvvalves.com\/ar\/wp-json\/wp\/v2\/users\/290641"}],"replies":[{"embeddable":true,"href":"https:\/\/www.stvvalves.com\/ar\/wp-json\/wp\/v2\/comments?post=8189"}],"version-history":[{"count":4,"href":"https:\/\/www.stvvalves.com\/ar\/wp-json\/wp\/v2\/posts\/8189\/revisions"}],"predecessor-version":[{"id":8196,"href":"https:\/\/www.stvvalves.com\/ar\/wp-json\/wp\/v2\/posts\/8189\/revisions\/8196"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.stvvalves.com\/ar\/wp-json\/wp\/v2\/media\/8195"}],"wp:attachment":[{"href":"https:\/\/www.stvvalves.com\/ar\/wp-json\/wp\/v2\/media?parent=8189"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.stvvalves.com\/ar\/wp-json\/wp\/v2\/categories?post=8189"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.stvvalves.com\/ar\/wp-json\/wp\/v2\/tags?post=8189"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}