{"id":5248,"date":"2019-08-02T06:23:20","date_gmt":"2019-08-02T06:23:20","guid":{"rendered":"https:\/\/www.stvvalves.com\/?p=5248"},"modified":"2019-08-02T06:23:21","modified_gmt":"2019-08-02T06:23:21","slug":"correct-installation-of-the-butterfly-valve","status":"publish","type":"post","link":"https:\/\/www.stvvalves.com\/es\/correct-installation-of-the-butterfly-valve\/","title":{"rendered":"Instalaci\u00f3n correcta de la v\u00e1lvula de mariposa."},"content":{"rendered":"<p>1, la posici\u00f3n de instalaci\u00f3n, la altura, la direcci\u00f3n de importaci\u00f3n y exportaci\u00f3n deben cumplir con los requisitos de dise\u00f1o, la conexi\u00f3n debe ser firme y compacta 0,2), todo tipo de v\u00e1lvulas manuales instaladas en la tuber\u00eda de aislamiento, las manijas no deben estar hacia abajo.<br>\n2, la v\u00e1lvula debe inspeccionarse visualmente antes de la instalaci\u00f3n, la placa de identificaci\u00f3n de la v\u00e1lvula debe cumplir con la norma nacional actual &quot;Marca general de v\u00e1lvulas&quot; GB 12220. Para v\u00e1lvulas con una presi\u00f3n de trabajo superior a 1,0 MPa y una funci\u00f3n de cierre en el principal Tuber\u00eda, las pruebas de resistencia y rendimiento herm\u00e9tico se llevar\u00e1n a cabo antes de la instalaci\u00f3n y se utilizar\u00e1n despu\u00e9s de pasar la prueba. En la prueba de resistencia, la presi\u00f3n de prueba es 1,5 veces la presi\u00f3n nominal, la duraci\u00f3n no es inferior a 5 minutos y la carcasa de la v\u00e1lvula y la empaquetadura deben estar calificadas sin fugas. En la prueba rigurosa, la presi\u00f3n de prueba es 1,1 veces la presi\u00f3n nominal; la presi\u00f3n de prueba deber\u00e1 cumplir con los requisitos de GB 50243 durante la duraci\u00f3n de la prueba, y se calificar\u00e1 la fuga de la superficie de sellado de la v\u00e1lvula.<\/p>\n\n\n\n<p>La v\u00e1lvula de mariposa tipo wafer es uno de los tipos de v\u00e1lvulas m\u00e1s comunes en tuber\u00edas industriales. La estructura de la v\u00e1lvula de mariposa tipo oblea en s\u00ed es relativamente peque\u00f1a. Simplemente coloque la v\u00e1lvula de mariposa en el medio de las bridas en los dos extremos de la tuber\u00eda y use los pernos dobles para pasar a trav\u00e9s de las bridas y los pares de la tuber\u00eda. Las v\u00e1lvulas de mariposa con clip bloquean el medio fluido en la l\u00ednea. Las v\u00e1lvulas de mariposa tipo Wafer son especialmente adecuadas para lugares donde el espacio es limitado o donde la distancia entre tuber\u00edas es corta. Cuando la v\u00e1lvula de mariposa est\u00e1 en la posici\u00f3n completamente abierta, el grosor de la placa de mariposa es la \u00fanica resistencia cuando el medio fluye a trav\u00e9s del cuerpo de la v\u00e1lvula, por lo que la ca\u00edda de presi\u00f3n generada por la v\u00e1lvula es muy baja. Peque\u00f1o, por lo que tiene mejores caracter\u00edsticas de control de flujo.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"1021\" height=\"583\" src=\"https:\/\/www.stvvalves.com\/wp-content\/uploads\/2019\/08\/1.jpg\" alt=\"\" class=\"wp-image-5249\" srcset=\"https:\/\/www.stvvalves.com\/wp-content\/uploads\/2019\/08\/1.jpg 1021w, https:\/\/www.stvvalves.com\/wp-content\/uploads\/2019\/08\/1-600x343.jpg 600w, https:\/\/www.stvvalves.com\/wp-content\/uploads\/2019\/08\/1-300x171.jpg 300w, https:\/\/www.stvvalves.com\/wp-content\/uploads\/2019\/08\/1-768x439.jpg 768w, https:\/\/www.stvvalves.com\/wp-content\/uploads\/2019\/08\/1-705x403.jpg 705w\" sizes=\"auto, (max-width: 1021px) 100vw, 1021px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"885\" height=\"361\" src=\"https:\/\/www.stvvalves.com\/wp-content\/uploads\/2019\/08\/2.jpg\" alt=\"\" class=\"wp-image-5250\" srcset=\"https:\/\/www.stvvalves.com\/wp-content\/uploads\/2019\/08\/2.jpg 885w, https:\/\/www.stvvalves.com\/wp-content\/uploads\/2019\/08\/2-600x245.jpg 600w, https:\/\/www.stvvalves.com\/wp-content\/uploads\/2019\/08\/2-300x122.jpg 300w, https:\/\/www.stvvalves.com\/wp-content\/uploads\/2019\/08\/2-768x313.jpg 768w, https:\/\/www.stvvalves.com\/wp-content\/uploads\/2019\/08\/2-705x288.jpg 705w\" sizes=\"auto, (max-width: 885px) 100vw, 885px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"902\" height=\"407\" src=\"https:\/\/www.stvvalves.com\/wp-content\/uploads\/2019\/08\/3.jpg\" alt=\"\" class=\"wp-image-5251\" srcset=\"https:\/\/www.stvvalves.com\/wp-content\/uploads\/2019\/08\/3.jpg 902w, https:\/\/www.stvvalves.com\/wp-content\/uploads\/2019\/08\/3-600x271.jpg 600w, https:\/\/www.stvvalves.com\/wp-content\/uploads\/2019\/08\/3-300x135.jpg 300w, https:\/\/www.stvvalves.com\/wp-content\/uploads\/2019\/08\/3-768x347.jpg 768w, https:\/\/www.stvvalves.com\/wp-content\/uploads\/2019\/08\/3-705x318.jpg 705w\" sizes=\"auto, (max-width: 902px) 100vw, 902px\" \/><\/figure>","protected":false},"excerpt":{"rendered":"<p>1, the installation position, height, import and export direction must meet the design requirements, the connection should be firm and compact 0.2), all kinds of manual valves installed on the insulation pipe, the handles must not be downward. 2, the valve must be visually inspected before installation, the nameplate of the valve should comply with [&hellip;]<\/p>\n","protected":false},"author":290641,"featured_media":5251,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[16],"tags":[1222,1218,1219,1220,1221],"class_list":["post-5248","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-news","tag-installation-of-a-butterfly-valve","tag-installation-of-butterfly-valve","tag-installation-of-butterfly-valve-wafer-type","tag-installation-of-lug-butterfly-valve","tag-installation-of-lug-type-butterfly-valve"],"_links":{"self":[{"href":"https:\/\/www.stvvalves.com\/es\/wp-json\/wp\/v2\/posts\/5248","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.stvvalves.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.stvvalves.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.stvvalves.com\/es\/wp-json\/wp\/v2\/users\/290641"}],"replies":[{"embeddable":true,"href":"https:\/\/www.stvvalves.com\/es\/wp-json\/wp\/v2\/comments?post=5248"}],"version-history":[{"count":0,"href":"https:\/\/www.stvvalves.com\/es\/wp-json\/wp\/v2\/posts\/5248\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.stvvalves.com\/es\/wp-json\/wp\/v2\/media\/5251"}],"wp:attachment":[{"href":"https:\/\/www.stvvalves.com\/es\/wp-json\/wp\/v2\/media?parent=5248"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.stvvalves.com\/es\/wp-json\/wp\/v2\/categories?post=5248"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.stvvalves.com\/es\/wp-json\/wp\/v2\/tags?post=5248"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}