{"id":8731,"date":"2025-12-30T22:35:10","date_gmt":"2025-12-30T14:35:10","guid":{"rendered":"https:\/\/www.stvvalves.com\/?p=8731"},"modified":"2025-12-30T22:38:45","modified_gmt":"2025-12-30T14:38:45","slug":"a-complete-guide-to-the-features-of-the-150lb-y-type-strainer","status":"publish","type":"post","link":"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/","title":{"rendered":"A Complete Guide to the Features of the 150LB Y Type Strainer"},"content":{"rendered":"<section id=\"introduction\">\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_82_2 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-1'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#A_Complete_Guide_to_the_Features_of_the_150LB_Y_Type_Strainer\" >A Complete Guide to the Features of the 150LB Y Type Strainer<\/a><ul class='ez-toc-list-level-2' ><li class='ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#Key_Features_and_Specifications_of_150LB_Y_Type_Strainer\" >Key Features and Specifications of 150LB Y Type Strainer<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#Pressure_Rating_and_Classification\" >Pressure Rating and Classification<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#Design_and_Construction_Materials\" >Design and Construction Materials<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#Need_Help_Selecting_the_Right_Material\" >Need Help Selecting the Right Material?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#Strainer_ScreenMesh_Specifications\" >Strainer Screen\/Mesh Specifications<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#Connection_Types_and_Standards\" >Connection Types and Standards<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#Advantages_and_Applications_of_150LB_Y_Type_Strainer\" >Advantages and Applications of 150LB Y Type Strainer<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#Key_Advantages\" >Key Advantages<\/a><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#Advantages_of_Y_Type_Strainers\" >Advantages of Y Type Strainers<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#Limitations_to_Consider\" >Limitations to Consider<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#Common_Industrial_Applications\" >Common Industrial Applications<\/a><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#Oil_and_Gas\" >Oil and Gas<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#Water_Treatment\" >Traitement de l&#039;eau<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#Steam_Systems\" >Steam Systems<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-16\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#Chemical_Processing\" >Chemical Processing<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-17\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#HVAC_Systems\" >HVAC Systems<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-18\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#Food_and_Beverage\" >Food and Beverage<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-19\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#Find_the_Perfect_Y_Type_Strainer_for_Your_Application\" >Find the Perfect Y Type Strainer for Your Application<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-20\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#Selection_and_Sizing_Considerations\" >Selection and Sizing Considerations<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-21\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#Key_Selection_Factors\" >Key Selection Factors<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-22\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#Sizing_Methodology\" >Sizing Methodology<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-23\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#Installation_Maintenance_and_Cleaning\" >Installation, Maintenance, and Cleaning<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-24\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#Installation_Best_Practices\" >Installation Best Practices<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-25\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#Maintenance_Procedures\" >Maintenance Procedures<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-26\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#Cleaning_Methods\" >Cleaning Methods<\/a><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-27\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#Blow-down_Cleaning\" >Blow-down Cleaning<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-28\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#Screen_Removal_and_Cleaning\" >Screen Removal and Cleaning<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-29\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#Need_Replacement_Screens_or_Maintenance_Kits\" >Need Replacement Screens or Maintenance Kits?<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-30\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#Comparison_with_Other_Strainer_Types\" >Comparison with Other Strainer Types<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-31\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#Pressure_Class_Comparison\" >Pressure Class Comparison<\/a><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-32\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#150LB_Class\" >150LB Class<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-33\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#300LB_Class\" >300LB Class<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-34\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#600LB_Class_and_Higher\" >600LB Class and Higher<\/a><\/li><\/ul><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-35\" href=\"https:\/\/www.stvvalves.com\/fr\/a-complete-guide-to-the-features-of-the-150lb-y-type-strainer\/#Conclusion\" >Conclusion<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h1><span class=\"ez-toc-section\" id=\"A_Complete_Guide_to_the_Features_of_the_150LB_Y_Type_Strainer\"><\/span>A Complete Guide to the Features of the 150LB Y Type Strainer<span class=\"ez-toc-section-end\"><\/span><\/h1>\n<p>In industrial pipeline systems, protecting equipment from debris and foreign particles is crucial for operational efficiency and longevity. The 150LB<a href=\"https:\/\/www.stvvalves.com\/fr\/products\/150lb-y-type-strainer-10-inch-astm-a216-wcb-body-40-mesh-ss304-screen-bw-end\/\"> Y Type Strainer<\/a> serves as a vital component in this protection strategy, acting as a mechanical filter that removes solid contaminants from fluid flow. This comprehensive guide explores the features, specifications, applications, and maintenance requirements of this essential industrial component, providing valuable insights for engineers, procurement specialists, and maintenance personnel.<\/p>\n<div class=\"img-container\">\n<div class=\"image-embed\" data-image=\"%7B%22src%22%3A%22https%3A%2F%2Fstorage.googleapis.com%2F48877118-7272-4a4d-b302-0465d8aa4548%2F7c0162ef-88b5-4cf7-9ba9-cc48ad7031d3%2F438e02c9-9198-4d73-9d5b-53884dd24973.jpg%22%2C%22title%22%3A%22150LB%20Y%20Type%20Strainer%20installed%20in%20an%20industrial%20pipeline%20system%22%2C%22method%22%3A%22text-to-image%22%2C%22generator%22%3A%222%22%2C%22date%22%3A1767098541945%7D\">\n<div class=\"_Media_1itgw_1 _ImageEmbed_1itgw_28\">\n<p><img decoding=\"async\" src=\"https:\/\/storage.googleapis.com\/48877118-7272-4a4d-b302-0465d8aa4548\/7c0162ef-88b5-4cf7-9ba9-cc48ad7031d3\/438e02c9-9198-4d73-9d5b-53884dd24973.jpg\" alt=\"150LB Y Type Strainer installed in an industrial pipeline system\" \/><\/p>\n<div class=\"_Buttons_1itgw_5\" contenteditable=\"false\" data-media=\"true\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"key-features\">\n<h2><span class=\"ez-toc-section\" id=\"Key_Features_and_Specifications_of_150LB_Y_Type_Strainer\"><\/span>Key Features and Specifications of 150LB Y Type Strainer<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>The 150LB<a href=\"https:\/\/www.buyfittingsonline.com\/stainless-steel-1-in-cf8m-flanged-y-strainer-ansi-150-316ss-ys41w6f\/150-100\/\" target=\"_blank\" rel=\"noopener\"> Y Type Strainer<\/a> is characterized by its distinctive Y-shaped body design, which allows for efficient fluid flow while effectively capturing debris. Understanding its key features and specifications is essential for selecting the right strainer for your specific application requirements.<\/p>\n<div class=\"img-container\">\n<div class=\"image-embed\" data-image=\"%7B%22src%22%3A%22https%3A%2F%2Fstorage.googleapis.com%2F48877118-7272-4a4d-b302-0465d8aa4548%2F7c0162ef-88b5-4cf7-9ba9-cc48ad7031d3%2F7a09d8f5-30e8-405a-a7a2-bf992adf8cbd.jpg%22%2C%22title%22%3A%22Cutaway%20view%20of%20a%20150LB%20Y%20Type%20Strainer%20showing%20internal%20components%22%2C%22method%22%3A%22text-to-image%22%2C%22generator%22%3A%222%22%2C%22date%22%3A1767098541846%7D\">\n<div class=\"_Media_1itgw_1 _ImageEmbed_1itgw_28\">\n<p><img decoding=\"async\" src=\"https:\/\/storage.googleapis.com\/48877118-7272-4a4d-b302-0465d8aa4548\/7c0162ef-88b5-4cf7-9ba9-cc48ad7031d3\/7a09d8f5-30e8-405a-a7a2-bf992adf8cbd.jpg\" alt=\"Cutaway view of a 150LB Y Type Strainer showing internal components\" \/><\/p>\n<div class=\"_Buttons_1itgw_5\" contenteditable=\"false\" data-media=\"true\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<h3><span class=\"ez-toc-section\" id=\"Pressure_Rating_and_Classification\"><\/span>Pressure Rating and Classification<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>The &#8220;150LB&#8221; designation refers to the pressure class according to ASME B16.34 standards. This classification indicates that the strainer is designed to handle specific maximum working pressures that vary depending on temperature and material. At ambient temperatures, a 150LB rated strainer typically handles working pressures up to 285 PSI for carbon steel and 275 PSI for stainless steel constructions.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Design_and_Construction_Materials\"><\/span>Design and Construction Materials<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Y Type Strainers are available in various materials to suit different applications and media compatibility requirements:<\/p>\n<div class=\"table-container\">\n<table class=\"responsive-table responsive-table-striped\">\n<thead>\n<tr>\n<td data-row=\"head\">Mat\u00e9riel<\/td>\n<td data-row=\"head\">ASTM Designation<\/td>\n<td data-row=\"head\">Common Applications<\/td>\n<td data-row=\"head\">Temperature Range<\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td data-label=\"Material\">Acier Carbone<\/td>\n<td data-label=\"ASTM Designation\">A216 WCB<\/td>\n<td data-label=\"Common Applications\">Steam, oil, gas, general industrial<\/td>\n<td data-label=\"Temperature Range\">-29\u00b0C to +425\u00b0C<\/td>\n<\/tr>\n<tr>\n<td data-label=\"Material\">Acier inoxydable<\/td>\n<td data-label=\"ASTM Designation\">A351 CF8M (316)<\/td>\n<td data-label=\"Common Applications\">Corrosive media, food processing, pharmaceutical<\/td>\n<td data-label=\"Temperature Range\">-196\u00b0C to +538\u00b0C<\/td>\n<\/tr>\n<tr>\n<td data-label=\"Material\">Fonte<\/td>\n<td data-label=\"ASTM Designation\">A126 Class B<\/td>\n<td data-label=\"Common Applications\">Water, air, gas at moderate temperatures<\/td>\n<td data-label=\"Temperature Range\">-29\u00b0C to +232\u00b0C<\/td>\n<\/tr>\n<tr>\n<td data-label=\"Material\">Fonte Ductile<\/td>\n<td data-label=\"ASTM Designation\">A395<\/td>\n<td data-label=\"Common Applications\">Higher pressure applications than cast iron<\/td>\n<td data-label=\"Temperature Range\">-29\u00b0C to +345\u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"cta-block\">\n<h3 class=\"cta-block-title\"><span class=\"ez-toc-section\" id=\"Need_Help_Selecting_the_Right_Material\"><\/span>Need Help Selecting the Right Material?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p class=\"cta-block-text\">Our engineers can help you choose the optimal material for your specific application and operating conditions.<\/p>\n<p>Request Expert Consultation<\/p>\n<\/div>\n<h3><span class=\"ez-toc-section\" id=\"Strainer_ScreenMesh_Specifications\"><\/span>Strainer Screen\/Mesh Specifications<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>The filtering element is a critical component of any Y Type Strainer. The screen or mesh is typically made of stainless steel for durability and corrosion resistance, regardless of the body material. Common mesh sizes and their applications include:<\/p>\n<div class=\"two-columns\">\n<div>\n<ul class=\"custom-list\">\n<li><strong>Mesh 20<\/strong>: Coarse filtration, larger particles (0.841 mm openings)<\/li>\n<li><strong>Mesh 40<\/strong>: Medium filtration (0.420 mm openings)<\/li>\n<li><strong>Mesh 60<\/strong>: Standard filtration for most applications (0.250 mm openings)<\/li>\n<li><strong>Mesh 80<\/strong>: Fine filtration (0.177 mm openings)<\/li>\n<li><strong>Mesh 100<\/strong>: Very fine filtration (0.149 mm openings)<\/li>\n<\/ul>\n<\/div>\n<div>\n<div class=\"img-container\">\n<div class=\"image-embed\" data-image=\"%7B%22src%22%3A%22https%3A%2F%2Fstorage.googleapis.com%2F48877118-7272-4a4d-b302-0465d8aa4548%2F7c0162ef-88b5-4cf7-9ba9-cc48ad7031d3%2F9f206662-ae68-43d8-9fb8-ecb969b06288.jpg%22%2C%22title%22%3A%22Close-up%20of%20different%20mesh%20screens%20used%20in%20150LB%20Y%20Type%20Strainers%22%2C%22method%22%3A%22text-to-image%22%2C%22generator%22%3A%222%22%2C%22date%22%3A1767098541746%7D\">\n<div class=\"_Media_1itgw_1 _ImageEmbed_1itgw_28\">\n<p><img decoding=\"async\" src=\"https:\/\/storage.googleapis.com\/48877118-7272-4a4d-b302-0465d8aa4548\/7c0162ef-88b5-4cf7-9ba9-cc48ad7031d3\/9f206662-ae68-43d8-9fb8-ecb969b06288.jpg\" alt=\"Close-up of different mesh screens used in 150LB Y Type Strainers\" \/><\/p>\n<div class=\"_Buttons_1itgw_5\" contenteditable=\"false\" data-media=\"true\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<h3><span class=\"ez-toc-section\" id=\"Connection_Types_and_Standards\"><\/span>Connection Types and Standards<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>150LB Y Type Strainers are available with various end connections to integrate with different piping systems:<\/p>\n<ul class=\"custom-list\">\n<li><strong>Flanged Connections<\/strong>: Most common for 150LB class, conforming to ASME B16.5 standards with raised face (RF) being the standard facing type<\/li>\n<li><strong>Threaded Connections<\/strong>: For smaller sizes (typically up to 3 inches), following NPT (National Pipe Thread) standards<\/li>\n<li><strong>Socket Weld<\/strong>: For high-integrity connections in critical applications<\/li>\n<li><strong>Butt Weld<\/strong>: For permanent installation in welded piping systems<\/li>\n<\/ul>\n<div class=\"img-container\"><\/div>\n<\/section>\n<section id=\"advantages-applications\">\n<h2><span class=\"ez-toc-section\" id=\"Advantages_and_Applications_of_150LB_Y_Type_Strainer\"><\/span>Advantages and Applications of 150LB Y Type Strainer<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>The unique design and versatile construction of Y Type Strainers make them suitable for a wide range of industrial applications. Understanding their advantages and common use cases helps in making informed decisions for your specific requirements.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Key_Advantages\"><\/span>Key Advantages<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<div class=\"pros-cons\">\n<div class=\"pros\">\n<h4 class=\"pros-title\"><span class=\"ez-toc-section\" id=\"Advantages_of_Y_Type_Strainers\"><\/span>Advantages of Y Type Strainers<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<ul>\n<li>Compact design requiring minimal installation space<\/li>\n<li>Lower pressure drop compared to basket strainers<\/li>\n<li>Simple construction with fewer parts, enhancing reliability<\/li>\n<li>Cost-effective solution for most applications<\/li>\n<li>Can be installed in horizontal or vertical positions<\/li>\n<li>Easy access for screen cleaning and maintenance<\/li>\n<li>Available in a wide range of materials for various media<\/li>\n<\/ul>\n<\/div>\n<div class=\"cons\">\n<h4 class=\"cons-title\"><span class=\"ez-toc-section\" id=\"Limitations_to_Consider\"><\/span>Limitations to Consider<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<ul>\n<li>Limited dirt-holding capacity compared to basket strainers<\/li>\n<li>Requires system shutdown for screen cleaning<\/li>\n<li>Not ideal for applications with high concentrations of solids<\/li>\n<li>Vertical installation with downward flow may cause debris accumulation<\/li>\n<li>Screen access may be restricted in tight installation spaces<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<h3><span class=\"ez-toc-section\" id=\"Common_Industrial_Applications\"><\/span>Common Industrial Applications<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>The 150LB Y Type Strainer finds application across numerous industries and processes:<\/p>\n<div class=\"three-columns\">\n<div class=\"column-card\">\n<h4><span class=\"ez-toc-section\" id=\"Oil_and_Gas\"><\/span>Oil and Gas<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<ul>\n<li>Protection of pumps and compressors<\/li>\n<li>Filtration in fuel transfer lines<\/li>\n<li>Removal of scale and debris in process lines<\/li>\n<\/ul>\n<\/div>\n<div class=\"column-card\">\n<h4><span class=\"ez-toc-section\" id=\"Water_Treatment\"><\/span>Traitement de l&#039;eau<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<ul>\n<li>Protection of control valves and meters<\/li>\n<li>Removal of pipe scale and rust<\/li>\n<li>Filtration in chemical dosing systems<\/li>\n<\/ul>\n<\/div>\n<div class=\"column-card\">\n<h4><span class=\"ez-toc-section\" id=\"Steam_Systems\"><\/span>Steam Systems<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<ul>\n<li>Protection of steam traps<\/li>\n<li>Removal of pipe scale and welding debris<\/li>\n<li>Filtration before pressure reducing valves<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<div class=\"img-container\"><\/div>\n<div class=\"three-columns\">\n<div class=\"column-card\">\n<h4><span class=\"ez-toc-section\" id=\"Chemical_Processing\"><\/span>Chemical Processing<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<ul>\n<li>Protection of metering equipment<\/li>\n<li>Filtration of process fluids<\/li>\n<li>Removal of catalyst fines<\/li>\n<\/ul>\n<\/div>\n<div class=\"column-card\">\n<h4><span class=\"ez-toc-section\" id=\"HVAC_Systems\"><\/span>HVAC Systems<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<ul>\n<li>Protection of pumps and heat exchangers<\/li>\n<li>Removal of debris in chilled water lines<\/li>\n<li>Filtration in glycol systems<\/li>\n<\/ul>\n<\/div>\n<div class=\"column-card\">\n<h4><span class=\"ez-toc-section\" id=\"Food_and_Beverage\"><\/span>Food and Beverage<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<ul>\n<li>Protection of process equipment<\/li>\n<li>Filtration of CIP (Clean-in-Place) systems<\/li>\n<li>Removal of particulates in utility lines<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<div class=\"cta-block\">\n<h3 class=\"cta-block-title\"><span class=\"ez-toc-section\" id=\"Find_the_Perfect_Y_Type_Strainer_for_Your_Application\"><\/span>Find the Perfect Y Type Strainer for Your Application<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p class=\"cta-block-text\">Our extensive inventory includes 150LB Y Type Strainers in various materials and sizes to meet your specific requirements.<\/p>\n<p><a class=\"cta-btn\" href=\"https:\/\/www.stvvalves.com\/fr\/contact-us\/\" rel=\"nofollow\" data-link=\"true\" data-id=\"2\">Request a Quote<\/a><\/p>\n<\/div>\n<\/section>\n<section id=\"selection-sizing\">\n<h2><span class=\"ez-toc-section\" id=\"Selection_and_Sizing_Considerations\"><\/span>Selection and Sizing Considerations<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Selecting the appropriate 150LB Y Type Strainer involves careful consideration of several factors to ensure optimal performance and longevity. The following guidelines will help you make informed decisions when specifying a strainer for your application.<\/p>\n<div class=\"img-container\"><\/div>\n<h3><span class=\"ez-toc-section\" id=\"Key_Selection_Factors\"><\/span>Key Selection Factors<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<div class=\"table-container\">\n<table class=\"responsive-table responsive-table-bordered\">\n<thead>\n<tr>\n<td data-row=\"head\">Selection Factor<\/td>\n<td data-row=\"head\">Considerations<\/td>\n<td data-row=\"head\">Recommendations<\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td data-label=\"Selection Factor\">Pipe Size<\/td>\n<td data-label=\"Considerations\">The strainer should match the pipe size for proper flow characteristics<\/td>\n<td data-label=\"Recommendations\">Select a strainer with the same nominal size as the pipeline<\/td>\n<\/tr>\n<tr>\n<td data-label=\"Selection Factor\">Flow Rate<\/td>\n<td data-label=\"Considerations\">Excessive flow velocity can cause high pressure drop and premature wear<\/td>\n<td data-label=\"Recommendations\">Size strainer for flow velocity between 4-10 ft\/sec for liquids, 80-100 ft\/sec for steam\/gas<\/td>\n<\/tr>\n<tr>\n<td data-label=\"Selection Factor\">Pressure Requirements<\/td>\n<td data-label=\"Considerations\">System pressure must be within the strainer&#8217;s rated capacity<\/td>\n<td data-label=\"Recommendations\">Ensure the 150LB class is suitable for your maximum operating pressure and temperature<\/td>\n<\/tr>\n<tr>\n<td data-label=\"Selection Factor\">Media Compatibility<\/td>\n<td data-label=\"Considerations\">Material compatibility with the process fluid is critical<\/td>\n<td data-label=\"Recommendations\">WCB for non-corrosive applications, CF8M for corrosive services<\/td>\n<\/tr>\n<tr>\n<td data-label=\"Selection Factor\">Particle Size<\/td>\n<td data-label=\"Considerations\">The mesh size determines the smallest particle that will be trapped<\/td>\n<td data-label=\"Recommendations\">Select mesh based on the smallest particle size that must be removed<\/td>\n<\/tr>\n<tr>\n<td data-label=\"Selection Factor\">Dirt Load<\/td>\n<td data-label=\"Considerations\">High dirt load may require frequent cleaning<\/td>\n<td data-label=\"Recommendations\">Consider a basket strainer for high dirt load applications<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h3><span class=\"ez-toc-section\" id=\"Sizing_Methodology\"><\/span>Sizing Methodology<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Proper sizing of a Y Type Strainer is crucial to ensure adequate flow while maintaining effective filtration. The following steps outline a basic sizing methodology:<\/p>\n<ol class=\"list-numbers\">\n<li><strong>Determine the required flow rate<\/strong>\u00a0of the system in gallons per minute (GPM) or cubic feet per minute (CFM)<\/li>\n<li><strong>Calculate the flow velocity<\/strong>\u00a0based on the pipe size and flow rate<\/li>\n<li><strong>Check pressure drop charts<\/strong>\u00a0provided by manufacturers to ensure the pressure loss is acceptable<\/li>\n<li><strong>Consider the open area ratio<\/strong>\u00a0of the screen to the pipe cross-section (typically 3:1 or 4:1 is recommended)<\/li>\n<li><strong>Verify temperature and pressure ratings<\/strong>\u00a0are suitable for the application<\/li>\n<\/ol>\n<div class=\"img-container\"><\/div>\n<div class=\"highlight-box\">\n<p><strong>Important Note:<\/strong>\u00a0Undersized strainers can cause excessive pressure drop and reduced system efficiency, while oversized strainers may lead to unnecessary costs and space requirements. Always consult manufacturer&#8217;s sizing guidelines for specific products.<\/p>\n<\/div>\n<\/section>\n<section id=\"installation-maintenance\">\n<h2><span class=\"ez-toc-section\" id=\"Installation_Maintenance_and_Cleaning\"><\/span>Installation, Maintenance, and Cleaning<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Proper installation and regular maintenance of 150LB Y Type Strainers are essential for ensuring optimal performance and extended service life. Following industry best practices for installation, maintenance, and cleaning will help prevent issues and minimize downtime.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Installation_Best_Practices\"><\/span>Installation Best Practices<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<div class=\"two-columns\">\n<div>\n<ul class=\"custom-list\">\n<li><strong>Orientation:<\/strong>\u00a0Install with the screen\/basket pointing downward for horizontal pipelines to facilitate debris collection<\/li>\n<li><strong>Flow Direction:<\/strong>\u00a0Ensure flow follows the directional arrow on the strainer body<\/li>\n<li><strong>Clearance:<\/strong>\u00a0Provide sufficient clearance below the strainer for screen removal and cleaning<\/li>\n<li><strong>Support:<\/strong>\u00a0Properly support the piping to prevent stress on the strainer body<\/li>\n<li><strong>Joints\u00a0:<\/strong>\u00a0Use appropriate gasket material compatible with the process fluid<\/li>\n<li><strong>Blow-down Valve:<\/strong>\u00a0Install a blow-down valve on the drain connection for easy cleaning<\/li>\n<\/ul>\n<\/div>\n<div>\n<div class=\"img-container\"><\/div>\n<\/div>\n<\/div>\n<h3><span class=\"ez-toc-section\" id=\"Maintenance_Procedures\"><\/span>Maintenance Procedures<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Regular maintenance is crucial for ensuring the continued effectiveness of Y Type Strainers. A comprehensive maintenance program should include:<\/p>\n<ol class=\"list-numbers\">\n<li><strong>Regular Inspection:<\/strong>\u00a0Check for external leaks, corrosion, or damage to the strainer body<\/li>\n<li><strong>Pressure Monitoring:<\/strong>\u00a0Install pressure gauges before and after the strainer to monitor pressure drop<\/li>\n<li><strong>Scheduled Cleaning:<\/strong>\u00a0Establish a cleaning schedule based on system conditions and experience<\/li>\n<li><strong>Gasket Replacement:<\/strong>\u00a0Replace gaskets whenever the strainer is opened for cleaning<\/li>\n<li><strong>Screen Inspection:<\/strong>\u00a0Check for damage, holes, or deformation in the screen during cleaning<\/li>\n<\/ol>\n<div class=\"img-container\"><\/div>\n<h3><span class=\"ez-toc-section\" id=\"Cleaning_Methods\"><\/span>Cleaning Methods<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>There are two primary methods for cleaning Y Type Strainers:<\/p>\n<div class=\"two-columns\">\n<div class=\"column-card\">\n<h4><span class=\"ez-toc-section\" id=\"Blow-down_Cleaning\"><\/span>Blow-down Cleaning<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>For strainers equipped with a blow-down valve:<\/p>\n<ol>\n<li>Partially close the outlet valve to reduce flow<\/li>\n<li>Open the blow-down valve for 5-10 seconds<\/li>\n<li>Close the blow-down valve<\/li>\n<li>Return the outlet valve to normal position<\/li>\n<li>Repeat if necessary<\/li>\n<\/ol>\n<p><strong>Note:<\/strong>\u00a0This method is suitable for light debris loads and when system shutdown is not possible.<\/p>\n<\/div>\n<div class=\"column-card\">\n<h4><span class=\"ez-toc-section\" id=\"Screen_Removal_and_Cleaning\"><\/span>Screen Removal and Cleaning<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>For thorough cleaning:<\/p>\n<ol>\n<li>Shut down the system and isolate the strainer<\/li>\n<li>Relieve pressure and drain the strainer<\/li>\n<li>Remove the screen access cover<\/li>\n<li>Extract the screen carefully<\/li>\n<li>Clean with appropriate solvent or brushing<\/li>\n<li>Inspect for damage and replace if necessary<\/li>\n<li>Reinstall with new gasket<\/li>\n<\/ol>\n<\/div>\n<\/div>\n<div class=\"warning-box\">\n<p><strong>Safety Warning:<\/strong>\u00a0Always ensure the system is depressurized and drained before opening the strainer for cleaning. Follow appropriate lockout\/tagout procedures and wear personal protective equipment.<\/p>\n<\/div>\n<div class=\"cta-block\">\n<h3 class=\"cta-block-title\"><span class=\"ez-toc-section\" id=\"Need_Replacement_Screens_or_Maintenance_Kits\"><\/span>Need Replacement Screens or Maintenance Kits?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p class=\"cta-block-text\">We offer a complete range of replacement screens, gaskets, and maintenance kits for all 150LB Y Type Strainers.<\/p>\n<p>Shop Maintenance Parts<\/p>\n<\/div>\n<\/section>\n<section id=\"comparison\">\n<h2><span class=\"ez-toc-section\" id=\"Comparison_with_Other_Strainer_Types\"><\/span>Comparison with Other Strainer Types<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>While 150LB Y Type Strainers are versatile and widely used, understanding how they compare to other strainer types can help in selecting the most appropriate solution for specific applications.<\/p>\n<div class=\"img-container\"><\/div>\n<div class=\"table-container\">\n<table class=\"responsive-table responsive-table-striped responsive-table-bordered\">\n<thead>\n<tr>\n<td data-row=\"head\">Feature<\/td>\n<td data-row=\"head\">Y Type Strainer (150LB)<\/td>\n<td data-row=\"head\">Cr\u00e9pine \u00e0 panier<\/td>\n<td data-row=\"head\">T Type Strainer<\/td>\n<td data-row=\"head\">Temporary Cone Strainer<\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td data-label=\"Feature\">Design<\/td>\n<td data-label=\"Y Type Strainer (150LB)\">Y-shaped body with angled screen<\/td>\n<td data-label=\"Basket Strainer\">Straight body with cylindrical basket<\/td>\n<td data-label=\"T Type Strainer\">T-shaped body with horizontal basket<\/td>\n<td data-label=\"Temporary Cone Strainer\">Conical insert between flanges<\/td>\n<\/tr>\n<tr>\n<td data-label=\"Feature\">Dirt Holding Capacity<\/td>\n<td data-label=\"Y Type Strainer (150LB)\">Moderate<\/td>\n<td data-label=\"Basket Strainer\">High<\/td>\n<td data-label=\"T Type Strainer\">Very High<\/td>\n<td data-label=\"Temporary Cone Strainer\">Low<\/td>\n<\/tr>\n<tr>\n<td data-label=\"Feature\">Pressure Drop<\/td>\n<td data-label=\"Y Type Strainer (150LB)\">Low to Moderate<\/td>\n<td data-label=\"Basket Strainer\">Moderate<\/td>\n<td data-label=\"T Type Strainer\">Moderate to High<\/td>\n<td data-label=\"Temporary Cone Strainer\">High<\/td>\n<\/tr>\n<tr>\n<td data-label=\"Feature\">Installation Space<\/td>\n<td data-label=\"Y Type Strainer (150LB)\">Compact<\/td>\n<td data-label=\"Basket Strainer\">Requires vertical clearance<\/td>\n<td data-label=\"T Type Strainer\">Requires horizontal clearance<\/td>\n<td data-label=\"Temporary Cone Strainer\">Minimal<\/td>\n<\/tr>\n<tr>\n<td data-label=\"Feature\">Maintenance Access<\/td>\n<td data-label=\"Y Type Strainer (150LB)\">Good<\/td>\n<td data-label=\"Basket Strainer\">Excellent<\/td>\n<td data-label=\"T Type Strainer\">Excellent<\/td>\n<td data-label=\"Temporary Cone Strainer\">Poor (requires disassembly)<\/td>\n<\/tr>\n<tr>\n<td data-label=\"Feature\">Cost<\/td>\n<td data-label=\"Y Type Strainer (150LB)\">Economical<\/td>\n<td data-label=\"Basket Strainer\">Moderate<\/td>\n<td data-label=\"T Type Strainer\">Higher<\/td>\n<td data-label=\"Temporary Cone Strainer\">Low<\/td>\n<\/tr>\n<tr>\n<td data-label=\"Feature\">Best For<\/td>\n<td data-label=\"Y Type Strainer (150LB)\">General purpose, clean to moderately dirty systems<\/td>\n<td data-label=\"Basket Strainer\">High dirt load, continuous operation<\/td>\n<td data-label=\"T Type Strainer\">Very high dirt load, critical applications<\/td>\n<td data-label=\"Temporary Cone Strainer\">System startup, temporary protection<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h3><span class=\"ez-toc-section\" id=\"Pressure_Class_Comparison\"><\/span>Pressure Class Comparison<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Y Type Strainers are available in different pressure classes to accommodate various system requirements:<\/p>\n<div class=\"three-columns\">\n<div class=\"column-card\">\n<h4><span class=\"ez-toc-section\" id=\"150LB_Class\"><\/span>150LB Class<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<ul>\n<li>Standard for most industrial applications<\/li>\n<li>Working pressure up to 285 PSI (carbon steel) at ambient temperature<\/li>\n<li>Most economical option<\/li>\n<li>Widest range of sizes and materials<\/li>\n<\/ul>\n<\/div>\n<div class=\"column-card\">\n<h4><span class=\"ez-toc-section\" id=\"300LB_Class\"><\/span>300LB Class<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<ul>\n<li>Higher pressure applications<\/li>\n<li>Working pressure up to 740 PSI (carbon steel) at ambient temperature<\/li>\n<li>Thicker body walls and stronger construction<\/li>\n<li>Suitable for more demanding service conditions<\/li>\n<\/ul>\n<\/div>\n<div class=\"column-card\">\n<h4><span class=\"ez-toc-section\" id=\"600LB_Class_and_Higher\"><\/span>600LB Class and Higher<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<ul>\n<li>High-pressure applications<\/li>\n<li>Working pressure up to 1480 PSI (carbon steel) at ambient temperature<\/li>\n<li>Heavy-duty construction<\/li>\n<li>Specialized applications in power generation, oil &amp; gas<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<div class=\"img-container\"><\/div>\n<\/section>\n<section id=\"conclusion\">\n<h2><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span>Conclusion<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>The 150LB Y Type Strainer is a versatile, cost-effective solution for protecting valuable equipment from debris and contaminants in pipeline systems. Its distinctive Y-shaped design offers an optimal balance of filtration efficiency, pressure drop performance, and ease of maintenance, making it suitable for a wide range of industrial applications.<\/p>\n<p>When selecting a Y Type Strainer, careful consideration of factors such as material compatibility, pressure and temperature requirements, flow characteristics, and maintenance needs will ensure optimal performance and longevity. Proper installation, regular maintenance, and appropriate cleaning procedures are essential for maximizing the effectiveness and service life of these critical components.<\/p>\n<p>Whether for steam systems, water treatment, chemical processing, or oil and gas applications, the 150LB Y Type Strainer continues to be a reliable choice for engineers and maintenance professionals seeking to protect their equipment and ensure<\/p>\n<\/section>","protected":false},"excerpt":{"rendered":"<p>A Complete Guide to the Features of the 150LB Y Type Strainer In industrial pipeline systems, protecting equipment from debris and foreign particles is crucial for operational efficiency and longevity. The 150LB Y Type Strainer serves as a vital component in this protection strategy, acting as a mechanical filter that removes solid contaminants from fluid [&hellip;]<\/p>\n","protected":false},"author":290641,"featured_media":6444,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[16],"tags":[3891,3890],"class_list":["post-8731","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-news","tag-features-of-the-150lb-y-type-strainer","tag-y-type-strainers"],"_links":{"self":[{"href":"https:\/\/www.stvvalves.com\/fr\/wp-json\/wp\/v2\/posts\/8731","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.stvvalves.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.stvvalves.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.stvvalves.com\/fr\/wp-json\/wp\/v2\/users\/290641"}],"replies":[{"embeddable":true,"href":"https:\/\/www.stvvalves.com\/fr\/wp-json\/wp\/v2\/comments?post=8731"}],"version-history":[{"count":3,"href":"https:\/\/www.stvvalves.com\/fr\/wp-json\/wp\/v2\/posts\/8731\/revisions"}],"predecessor-version":[{"id":8734,"href":"https:\/\/www.stvvalves.com\/fr\/wp-json\/wp\/v2\/posts\/8731\/revisions\/8734"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.stvvalves.com\/fr\/wp-json\/wp\/v2\/media\/6444"}],"wp:attachment":[{"href":"https:\/\/www.stvvalves.com\/fr\/wp-json\/wp\/v2\/media?parent=8731"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.stvvalves.com\/fr\/wp-json\/wp\/v2\/categories?post=8731"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.stvvalves.com\/fr\/wp-json\/wp\/v2\/tags?post=8731"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}