{"id":9078,"date":"2026-11-27T20:03:10","date_gmt":"2026-11-27T12:03:10","guid":{"rendered":"https:\/\/www.stvvalves.com\/?post_type=product&#038;p=9078"},"modified":"2026-11-27T20:09:42","modified_gmt":"2026-11-27T12:09:42","slug":"ptfe-wafer-check-valve-hc276-3-inch-class-150","status":"publish","type":"product","link":"https:\/\/www.stvvalves.com\/fr\/products\/ptfe-wafer-check-valve-hc276-3-inch-class-150\/","title":{"rendered":"PTFE Wafer Check Valve, HC276 Body, 3 Inch, Class 150"},"content":{"rendered":"<h1 data-pm-slice=\"1 1 []\">PTFE Wafer Check Valve, HC276 Body, 3 Inch, Class 150 \u2013 Corrosion Resistant Industrial Check Valve<\/h1>\n<h2>1. Product Overview<\/h2>\n<p>Le <strong>3 Inch Class 150 PTFE Wafer Check Valve with HC276 Body<\/strong> is designed for industrial piping systems that require reliable backflow prevention and excellent corrosion resistance. Combining a Hastelloy C-276 alloy body with a PTFE-lined internal flow passage, this valve provides an effective solution for handling aggressive chemicals, corrosive liquids, and demanding industrial media.<\/p>\n<p>The HC276 body offers outstanding resistance to a wide range of corrosive environments, while the PTFE lining provides a chemically resistant contact surface that helps protect the valve interior from chemical attack.<\/p>\n<p>With a compact wafer-style design, this check valve can be installed between compatible pipeline flanges, helping reduce installation space and overall piping weight.<\/p>\n<p>STV VALVE supplies corrosion-resistant industrial check valves for chemical processing, petrochemical, pharmaceutical, and other demanding applications.<\/p>\n<h2>2. Key Product Specifications<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Parameter<\/th>\n<th>Description<\/th>\n<\/tr>\n<tr>\n<td>Nom du produit<\/td>\n<td>PTFE Wafer Check Valve<\/td>\n<\/tr>\n<tr>\n<td>Nominal Size<\/td>\n<td>3 Inch (DN80)<\/td>\n<\/tr>\n<tr>\n<td>Pressure Class<\/td>\n<td>ASME Class 150<\/td>\n<\/tr>\n<tr>\n<td>Body Material<\/td>\n<td>Hastelloy C-276 (HC276)<\/td>\n<\/tr>\n<tr>\n<td>Internal Lining<\/td>\n<td>PTFE<\/td>\n<\/tr>\n<tr>\n<td>Type de vanne<\/td>\n<td>Clapet anti-retour de plaquette<\/td>\n<\/tr>\n<tr>\n<td>Connexion<\/td>\n<td>Wafer Type, Between Flanges<\/td>\n<\/tr>\n<tr>\n<td>Fonction<\/td>\n<td>Automatic Backflow Prevention<\/td>\n<\/tr>\n<tr>\n<td>Op\u00e9ration<\/td>\n<td>Self-Actuated<\/td>\n<\/tr>\n<tr>\n<td>Application<\/td>\n<td>Corrosive Chemical Service<\/td>\n<\/tr>\n<tr>\n<td>Manufacturer<\/td>\n<td>STV VALVE<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><em>Note: Disc, spring, gasket, lining thickness, face-to-face dimensions, and applicable design standards should be confirmed according to the approved technical drawing and project requirements.<\/em><\/p>\n<h2>3. HC276 Body \u2013 Excellent Corrosion Resistance<\/h2>\n<p>Hastelloy C-276 (HC276) is a nickel-molybdenum-chromium alloy recognized for its excellent corrosion resistance in severe industrial environments.<\/p>\n<p>Compared with conventional stainless steel materials, HC276 offers improved resistance to many aggressive chemicals, particularly in environments containing chlorides, oxidizing agents, and reducing acids.<\/p>\n<p>Key material advantages include:<\/p>\n<ul data-spread=\"false\">\n<li>Excellent resistance to pitting and crevice corrosion.<\/li>\n<li>High resistance to chloride-induced corrosion.<\/li>\n<li>Good performance in various acidic chemical environments.<\/li>\n<li>Resistance to many oxidizing and reducing chemical media.<\/li>\n<li>Good mechanical properties in demanding industrial applications.<\/li>\n<\/ul>\n<p>The HC276 body makes this 3-inch wafer check valve suitable for applications where standard carbon steel and stainless steel valves may not provide sufficient corrosion resistance.<\/p>\n<h2>4. PTFE Lining \u2013 Chemical Protection and Reliable Sealing<\/h2>\n<p>PTFE (Polytetrafluoroethylene) is widely used as a lining material in chemical-processing valves because of its excellent chemical resistance and low friction coefficient.<\/p>\n<p>In this wafer check valve, the PTFE lining provides a protective barrier between the process medium and the valve&#8217;s internal surfaces.<\/p>\n<p>Main benefits of PTFE lining:<\/p>\n<ul data-spread=\"false\">\n<li>Excellent resistance to many acids and alkalis.<\/li>\n<li>Low friction and non-stick surface characteristics.<\/li>\n<li>Reduced risk of chemical attack on protected internal surfaces.<\/li>\n<li>Suitable for many corrosive liquid applications.<\/li>\n<li>Helps improve service life in compatible chemical environments.<\/li>\n<\/ul>\n<p>The chemical compatibility of PTFE must still be evaluated against the actual process medium, temperature, pressure, and operating conditions.<\/p>\n<h2>5. Working Principle of PTFE Wafer Check Valve<\/h2>\n<p>A wafer check valve is an automatic valve designed to prevent reverse flow in a pipeline.<\/p>\n<p>When the upstream pressure exceeds the downstream pressure and the required opening differential is achieved, the internal disc opens to allow fluid to pass through the valve.<\/p>\n<p>When the flow decreases or reverses, the disc returns toward the closed position, helping prevent backflow into the upstream pipeline.<\/p>\n<p>The main operating functions include:<\/p>\n<ol start=\"1\" data-spread=\"false\">\n<li>Forward Flow: The process medium pushes the disc open.<\/li>\n<li>Normal Operation: The valve maintains an open flow passage.<\/li>\n<li>Reverse Flow: The disc moves toward the closed position.<\/li>\n<li>Backflow Prevention: The valve helps protect pumps, pipelines, and other equipment.<\/li>\n<\/ol>\n<p>The actual opening pressure and closing performance depend on the internal design, disc configuration, and spring arrangement, if fitted.<\/p>\n<h2>6. Main Advantages of HC276 PTFE Wafer Check Valve<\/h2>\n<p><strong>1. Corrosion-Resistant Alloy Construction<\/strong><\/p>\n<p>The HC276 body is suitable for demanding chemical environments where corrosion resistance is a major selection requirement.<\/p>\n<p><strong>2. PTFE-Protected Internal Surface<\/strong><\/p>\n<p>The PTFE lining helps isolate compatible corrosive media from the valve&#8217;s protected internal surfaces.<\/p>\n<p><strong>3. Compact Wafer Design<\/strong><\/p>\n<p>The wafer configuration allows installation between compatible pipeline flanges, saving installation space.<\/p>\n<p><strong>4. Automatic Operation<\/strong><\/p>\n<p>No external actuator or manual operation is required. The valve responds automatically to flow and differential pressure.<\/p>\n<p><strong>5. Reduced Backflow Risk<\/strong><\/p>\n<p>The valve helps prevent reverse flow that could damage pumps, compressors, and other pipeline equipment.<\/p>\n<p><strong>6. Industrial Chemical Applications<\/strong><\/p>\n<p>The combination of HC276 alloy and PTFE lining makes the valve suitable for selected aggressive chemical services.<\/p>\n<h2>7. Typical Industrial Applications<\/h2>\n<p>The 3 Inch Class 150 HC276 PTFE Wafer Check Valve can be considered for the following applications, subject to chemical compatibility and engineering verification.<\/p>\n<h3>Chemical Processing Industry<\/h3>\n<p>Used in chemical transfer lines, acid circulation systems, and corrosive liquid pipelines.<\/p>\n<h3>Petrochemical Industry<\/h3>\n<p>Suitable for selected chemical processing and fluid handling systems involving aggressive media.<\/p>\n<h3>Pharmaceutical Industry<\/h3>\n<p>Can be considered for compatible chemical transfer and process utility systems.<\/p>\n<h3>Acid and Alkali Handling<\/h3>\n<p>Designed for selected acidic and alkaline fluid services where PTFE lining provides suitable chemical protection.<\/p>\n<h3>Industrial Wastewater Treatment<\/h3>\n<p>Used in compatible chemical dosing, treatment, and wastewater transfer systems.<\/p>\n<h2>8. Installation and Maintenance Recommendations<\/h2>\n<p>Correct installation is essential for reliable check valve performance.<\/p>\n<ul data-spread=\"false\">\n<li>Confirm that the pipeline flange dimensions match the valve design.<\/li>\n<li>Check the flow direction arrow before installation.<\/li>\n<li>Ensure that the PTFE lining is not damaged during transportation or installation.<\/li>\n<li>Use compatible gaskets and appropriate bolting materials.<\/li>\n<li>Tighten flange bolts evenly according to the specified torque requirements.<\/li>\n<li>Avoid excessive pipeline stress on the valve body.<\/li>\n<li>Inspect the valve periodically for leakage, deposits, and internal wear.<\/li>\n<\/ul>\n<p>The valve should be installed in the orientation specified by the manufacturer&#8217;s approved installation instructions.<\/p>\n<h2>9. Why Choose STV VALVE?<\/h2>\n<p>STV VALVE focuses on industrial valve manufacturing and supply for international customers in chemical processing, petrochemical, oil and gas, power generation, and general industrial markets.<\/p>\n<p>Our product range includes:<\/p>\n<ul data-spread=\"false\">\n<li>PTFE Lined Valves<\/li>\n<li>Wafer Check Valves<\/li>\n<li>Swing Check Valves<\/li>\n<li>Dual Plate Check Valves<\/li>\n<li>Titanium Valves<\/li>\n<li>Hastelloy Alloy Valves<\/li>\n<li>Stainless Steel Industrial Valves<\/li>\n<li>High-Pressure Industrial Valves<\/li>\n<\/ul>\n<p>For special alloy valve requirements, STV VALVE can work with customers to confirm material grades, pressure ratings, connection dimensions, lining materials, inspection requirements, and project-specific technical specifications.<\/p>\n<p>Website: <a href=\"https:\/\/www.stvvalves.com\/fr\/\" data-rich-text-autolink=\"\">https:\/\/www.stvvalves.com\/<\/a><\/p>\n<h2>10. Frequently Asked Questions (FAQ)<\/h2>\n<p><strong>Q1: What is an HC276 PTFE wafer check valve?<\/strong><\/p>\n<p>It is a non-return valve featuring a Hastelloy C-276 alloy body and PTFE-lined internal surfaces. It is designed to prevent reverse flow in corrosive industrial piping systems.<\/p>\n<p><strong>Q2: What are the advantages of an HC276 body?<\/strong><\/p>\n<p>HC276 provides excellent resistance to many aggressive chemical environments, including various chloride-containing and acidic media.<\/p>\n<p><strong>Q3: Why is PTFE used as the lining material?<\/strong><\/p>\n<p>PTFE offers excellent chemical resistance and a low-friction surface, making it suitable for protecting valve internals in many corrosive applications.<\/p>\n<p><strong>Q4: What does Class 150 mean?<\/strong><\/p>\n<p>Class 150 is an ASME pressure class designation. Its allowable working pressure depends on the material and operating temperature. It should not be interpreted as a universal 150 psi pressure rating.<\/p>\n<p><strong>Q5: What pipeline size is a 3-inch wafer check valve?<\/strong><\/p>\n<p>A nominal 3-inch valve generally corresponds to DN80. The actual flange compatibility and dimensional requirements should be verified against the applicable standard.<\/p>\n<p><strong>Q6: Can this valve be used for sulfuric acid or hydrochloric acid?<\/strong><\/p>\n<p>HC276 and PTFE are used in various acid-handling applications, but suitability depends on acid concentration, temperature, impurities, flow conditions, and the complete wetted-material configuration. A chemical compatibility review is recommended before ordering.<\/p>\n<p><strong>Q7: Does the wafer check valve require manual operation?<\/strong><\/p>\n<p>No. It operates automatically according to the direction of fluid flow and the pressure differential across the valve.<\/p>\n<p><strong>Q8: Can STV VALVE supply customized HC276 PTFE wafer check valves?<\/strong><\/p>\n<p>Yes. Special material combinations, dimensions, lining requirements, inspection documentation, and project specifications can be discussed with STV VALVE.<\/p>\n<h2>11. Conclusion<\/h2>\n<p>Le <strong>PTFE Wafer Check Valve, HC276 Body, 3 Inch, Class 150<\/strong> is a corrosion-resistant industrial valve solution for selected chemical and process applications.<\/p>\n<p>Its combination of Hastelloy C-276 alloy construction, PTFE-lined internal surfaces, and compact wafer-style installation makes it a practical choice for engineers and industrial buyers seeking reliable backflow prevention in corrosive fluid systems.<\/p>\n<p>Contact STV VALVE for technical specifications, material confirmation, drawings, and quotations.<\/p>\n<p><strong>STV VALVE \u2013 Industrial Valve Manufacturer and Supplier<\/strong><\/p>\n<p>Website: <a href=\"https:\/\/www.stvvalves.com\/fr\/\" data-rich-text-autolink=\"\">https:\/\/www.stvvalves.com\/<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>STV VALVE supplies 3 Inch Class 150 PTFE Wafer Check Valves with HC276 Hastelloy C-276 bodies for corrosive chemical applications. Explore specifications and advantages.<\/p>","protected":false},"featured_media":9079,"template":"","meta":[],"product_brand":[],"product_cat":[46,84],"product_tag":[4427,4428,4426,4425,4424],"class_list":["post-9078","product","type-product","status-publish","has-post-thumbnail","product_cat-check-valves","product_cat-wafer-check-valve","product_tag-3-inch-wafer-check-valve","product_tag-class-150-ptfe-check-valv","product_tag-hastelloy-c-276-check-valve","product_tag-hc276-wafer-check-valve","product_tag-ptfe-wafer-check-valve","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.stvvalves.com\/fr\/wp-json\/wp\/v2\/product\/9078","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.stvvalves.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.stvvalves.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.stvvalves.com\/fr\/wp-json\/wp\/v2\/media\/9079"}],"wp:attachment":[{"href":"https:\/\/www.stvvalves.com\/fr\/wp-json\/wp\/v2\/media?parent=9078"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.stvvalves.com\/fr\/wp-json\/wp\/v2\/product_brand?post=9078"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.stvvalves.com\/fr\/wp-json\/wp\/v2\/product_cat?post=9078"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.stvvalves.com\/fr\/wp-json\/wp\/v2\/product_tag?post=9078"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}